Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=cfc2f95d-8b44-43ce-957c-3707dcc0be61&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=5051a1ee-cb92-4489-870b-dc4215a79409&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=94bc96a1-1bab-43af-b350-7f9bfc70fbdd&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=f11af19d-1470-4936-8ae7-c6374991f06d&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=9cd5ab5e-803d-426c-99ac-52d3a2da81a0&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Error Loading: \_modules\spacer\v1\ucSpacerDefault.ascx&msid=00000000-0000-0000-0000-000000000000&spmid=2129e16b-580c-4352-8118-34235d2c0a18&pgid=c0540171-8e20-4f14-bf5a-b23d785f6b4f&siteid=70642d19-2b11-4db3-b0c3-5381ab598f27&locale=en&id=c0540171-8e20-4f14-bf5a-b23d785f6b4f& - The file '/_modules/spacer/v1/ucSpacerDefault.ascx' does not exist.
Ranch - Susquehanna Valley Builders Ltd

Our Homes

All of our homes include, but not limited to the following " Standard options":

  • 10" gable and eave overhangs

  • 7/12 16"o.c. engineered wood

  • 7/16" OSB roof sheathing

  • Full length attic ridge ventilating system

  • 6-panel interior hollow core doors

  • R-19 batt type wall insulation

  • House wrap weather barrier

  • 1/2" gypsum sheetrock - glued, screwed and foamed on exterior

  • 2"x6" exterior wall studding with double top plate 16"o.c.

  • 7/16" OSB sheathing, glued and fastened

  • Aluminum fascia and vinyl soffit

  • Architectural asphalt, self sealing shingles with 30 year warranty

  • 48" freeze barrier under shingles

  • Vinyl double-hung, insulating glass windows with full screens

  • 2"x10" stringers with pine tread and plywood risers

  • Exterior coach lights at front and rear doors

  • Door chime at front and rear doors

  • Exterior all weather GFI receptacles front and rear

  • Insulated fiberglass exterior door with no maintenance PVC frame

  • 1/2" gypsum drywall with smooth finish on walls and 5/8" fire rated type X gypsum on ceilings, two coats of white primer paint

  • 2"x4" interior studding with full 8' ceiling height 16"o.c.

  • FHA approved 25oz. plush carpet with 6# pad

  • 3/4" tongue & groove fully sanded OSB floor decking, glued and nailed

  • 2"x10" floor joist 16"o.c. with mild span blocking200 amp service panel with circuit breakers

  • 2"x10" double band joists

  • Double marriage band joists with 2"x2" ledge strip

  • Copper water lines and schedule 40 PVC waste and vent

  • Custom comfort, high gloss vinyl floor covering

  • Custom kitchen cabinets with recessed panel oak doors

  • 8" deep stainless steel kitchen sink

  • Custom Formica counter top

  • 36" wall cabinet above refrigerator space

  • Colonial-style wood window and door trim

  • Crown molding over kitchen cabinets

  • Wood sill on all windows

  • One piece fiberglass tub/shower with single lever anti-scald faucet

  • Vanity drawer base cabinet with cultured marble sink bowl and single lever faucet

  • R-30 batt type ceiling insulation

  • Low maintenance vinyl siding

  • Optional porches and decks

  • Metal Strapping

  • Gable end out lookers

  • Solid Cabinet Blocking